• Login
    • Login
    Advanced Search
    View Item 
    •   UoN Digital Repository Home
    • Journal Articles
    • Faculty of Health Sciences (FHS)
    • View Item
    •   UoN Digital Repository Home
    • Journal Articles
    • Faculty of Health Sciences (FHS)
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Evaluation of two commercially available alternatives for HIV-1 viral load testing in resource-limited settings

    Thumbnail
    View/Open
    ABSTRACT.pdf (57.18Kb)
    Date
    2007
    Author
    Steegen, Kim
    Luchters, Stanley
    Cabooter, Nancy De
    Reynaerts, Jacqueline
    Mandaliya, Kishor
    Plum, Jean
    Jaoko Walter G.
    Verhofstede, Chris
    Temmerman, M
    Type
    Article
    Language
    en
    Metadata
    Show full item record

    Abstract
    There is an urgent need for low-cost assays for HIV-1 quantitation to ensure adequate follow-up of HIV-infected patients on antiretroviral therapy (ART) in resource-limited countries. Two low-cost viral load assays are evaluated, a reverse transcriptase activity assay (ExavirLoad v2, Cavidi) and a real-time reverse transcriptase PCR assay (Generic HIV viral load, Biocentric). Both tests were compared with the ultrasensitive HIV Amplicor Monitor assay. Samples were collected in Mombasa, Kenya, from 20 HIV-1 seronegative and 150 HIV-1 seropositive individuals of whom 50 received antiretroviral treatment (ART). The ExavirLoad and the Generic HIV viral load assay were performed in a local laboratory in Mombasa, the Amplicor Monitor assay (version 1.5, Roche Diagnostics) was performed in Ghent, Belgium. ExavirLoad and Generic HIV viral load reached a sensitivity of 98.3% and 100% and a specificity of 80.0% and 90.0%, respectively. Linear regression analyses revealed good correlations between the Amplicor Monitor and the Generic HIV viral load (r = 0.935, p < 0.001) with high accuracy (100.1%), good precision (5.5%) and a low percent similarity coefficient of variation (5.4%). Bland–Altman analysis found 95% of the samples within clinically acceptable limits of agreement (−1.19 to 0.87 log copies/ml). Although, the ExavirLoad also showed a good linear correlation with the Amplicor Monitor (r = 0.901, p < 0.001), a problem with false positive results was more significant. The cost per test remains relatively high (US$ 30 for ExavirLoad and US$ 20 for the Generic HIV viral load). Hence, false positive results and the need for an expensive PCR instrument for the Generic HIV viral load assays still limit the implementation of these tests in less equipped, less experienced laboratories
    URI
    http://www.ncbi.nlm.nih.gov/pubmed/17686534
    http://erepository.uonbi.ac.ke:8080/xmlui/handle/123456789/10173
    Citation
    Journal of Virological Methods 146
    Subject
    HIV-1
    Low-cost viral load assay;
    Resource-limited countries
    Collections
    • Faculty of Health Sciences (FHS) [10418]

    Copyright © 2022 
    University of Nairobi Library
    Contact Us | Send Feedback

     

     

    Useful Links
    UON HomeLibrary HomeKLISC

    Browse

    All of UoN Digital RepositoryCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Copyright © 2022 
    University of Nairobi Library
    Contact Us | Send Feedback