    Design and Performance Assessment of a Low Cost Evaporative Cooler for Storage of Camel Milk in Arid Pastoral Areas of Kenya

    Thumbnail
    View/Open
    Abstract.PDF (23.41Kb)
    Date
    2012
    Author
    Wayua, Francis O
    Okoth, Michael W
    Wangoh, John
    Type
    Article
    Language
    en
    Metadata
    Show full item record

    Abstract
    A low-cost charcoal evaporative cooler was designed and tested for the storage of camel milk an arid pastoral area of northern Kenya.Thecooler,0.75m3incapacity,was made of galvanised iron frame reinforced with wire mesh inside and out, leaving a 10 cm-wide cavity which was filled with charcoal. A water reservoir linked to the cooler at the top through a perforated pipe kept the charcoal continuously wet through drip system. A wind driven fan on the roof enhanced air movement through the charcoal walls by sucking out the air in the cooler. The cooler was evaluated for temperature and product response. The inside temperature was 1-11°C lower than outside temperature and inside humidity was 0-49% higher than outside. During the hottest time of the day (14.00 hrs) when cooling was most needed, the cooler consistently maintained an average temperature drop of 10.5±0.4°C below ambient temperature, which varied from 29-32°C. This reduction in temperature was 35.6%andstatisticallysignificant(p≤0.05).Duringthistime,cooling efficiency varied between 74.2 to 86.7%. Temperature of camel milk inside the cooler did not significantly increase (p>0.05) between morning time and evening time. However, temperature of control milk at ambient conditions significantly (p≤0.05) changed over the same period, from 22.6±0.08°C to 28.1±0.08°C. Milk inside the cooler was also significantly cooler (p≤0.05) than control milk in the evening, with a net temperature reduction of 27.0%. Total bacterial count changed from 31.4±2.1 x 104 cfu/ml to 43.1±1.9 x 104 and 1638±81 x 104 cfu/ml for test and control milk, respectively, after storage for 10 hours. As an inexpensive alternative to mechanical refrigeration, evaporative cooling technology is promising and suitable for rural application in arid pastoral areas without grid electricity, to minimise risk of milk spoilage at collection points and retail level, and thereby encourage organised women groups to get involved in milk marketing as a source of income.
    URI
    http://erepository.uonbi.ac.ke:8080/xmlui/handle/123456789/10747
    Citation
    International Journal of Food Engineering Volume 8,Issue 1 2012 Article 16
    Publisher
    Department of Food Science Nutrition and Technology
    Subject
    Design
    Evaporative cooler
    Camel Milk Storage
    Arid areas
    Collections
    • Faculty of Agriculture & Veterinary Medicine (FAg / FVM) [5481]

    Copyright © 2022 
    University of Nairobi Library
    Contact Us | Send Feedback

     

     

    Useful Links
    UON HomeLibrary HomeKLISC

    Browse

    All of UoN Digital RepositoryCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Copyright © 2022 
    University of Nairobi Library
    Contact Us | Send Feedback