• Login
    • Login
    Advanced Search
    View Item 
    •   UoN Digital Repository Home
    • Journal Articles
    • Faculty of Health Sciences (FHS)
    • View Item
    •   UoN Digital Repository Home
    • Journal Articles
    • Faculty of Health Sciences (FHS)
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Assessing the accuracy of presumptive distal femoral cuts in the conduct of conventional total knee replacement in Kenyan patients with end stage osteoarthritis of the knee

    Thumbnail
    View/Open
    Full-text (331.8Kb)
    Date
    2021-10-18
    Author
    Murerwa, M.
    Mulimba, J. A. O.
    Gakuya, E. M.
    Type
    Article
    Language
    en_US
    Metadata
    Show full item record

    Abstract
    Background: Total Knee Replacements in our setting are performed using conventional techniques. This involves use of an intramedullary rod and jig to perform the Distal Femoral Cut (DFC). Ideally the magnitude of the Valgus Correction Angle (VCA) used to perform the DFC should equal the angle subtended by the femoral anatomical and mechanical axes at the knee. This relationship can be determined preoperatively using whole lower limb radiographs or presumed to be ideal and of a magnitude between 50 and 70 (60 being common). Assumption may be erroneous given the influence of Coronal Femoral Bowing (CFB) and the Neck Shaft Angle (NSA) on the relationship. Objective: The purpose of this study was to determine the accuracy of presumptive cuts in our setting. Methods: This was a cross sectional study in four orthopaedic centers in Kenya namely Kenyatta National Hospital (KNH), St Francis Community Hospital Kasarani, PCEA Kikuyu Hospital and the Aga Khan University Hospital Nairobi. Patients with end stage osteoarthritis of the knee scheduled for surgery were screened. Whole lower limb radiographs with limbs in 150 of internal rotation were taken and used to determine the VCA, CFB and NSA. The rate of error with use of presumptive cuts within prescribed limits was then determined. Results: Eighty two limbs in 48 patients were studied. Fifty nine were in varus 21 in valgus and 2 in neutral alignment. The average VCA for all libs was 6.290 (sd 1.800 ). Considering only limbs in varus alignment the VCA averaged 6.510 (sd 1.950 ). Use of presumptive cuts of 60 in these limbs would potentially result in erroneous cuts in 9.8% of limbs in varus alignment. There was a strong positive correlation between CFB and the VCA. Conclusions: Routine use of whole lower limb radiographs could improve the accuracy of DFC. In their absence use a VCA of greater magnitude within the prescribed limits in patients with significant clinical varus alignment
    URI
    https://www.ajol.info/index.php/eaoj/issue/view/20117
    http://erepository.uonbi.ac.ke/handle/11295/155914
    Citation
    Murerwa, M., Mulimba, J. A. O., & Gakuya, E. M. (2021). Assessing the accuracy of presumptive distal femoral cuts in the conduct of conventional total knee replacement in Kenyan patients with end stage osteoarthritis of the knee. East African Orthopaedic Journal, 15(2), 71-78.
    Publisher
    East African Orthopaedic Journal
    Subject
    : Valgus correction angle, Coronal femoral bowing, Distal femoral cut, Neck Shaft Angle, Total Knee Replacement
    Collections
    • Faculty of Health Sciences (FHS) [10415]

    Copyright © 2022 
    University of Nairobi Library
    Contact Us | Send Feedback

     

     

    Useful Links
    UON HomeLibrary HomeKLISC

    Browse

    All of UoN Digital RepositoryCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Copyright © 2022 
    University of Nairobi Library
    Contact Us | Send Feedback