• Login
    • Login
    Advanced Search
    View Item 
    •   UoN Digital Repository Home
    • Journal Articles
    • Faculty of Health Sciences (FHS)
    • View Item
    •   UoN Digital Repository Home
    • Journal Articles
    • Faculty of Health Sciences (FHS)
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Radiation Exposure In Interventional Procedures

    Thumbnail
    View/Open
    Abstract.pdf (8.123Kb)
    Date
    2012
    Author
    Korir, G. K
    Ochieng, B. O
    Wambani, J. S
    Korir, I. K
    Yuko, Jowi C.
    Type
    Article
    Language
    en
    Metadata
    Show full item record

    Abstract
    The aim of this study was to estimate radiation doses patients and staff are exposed to during interventional procedures (IPs), compare them with the international diagnostic reference levels and to develop initial National Diagnostic Reference Levels. The IP survey was undertaken as the initial task of which, retrospective data were collected from the only four Kenyan hospitals carrying out interventional radiology and cardiology procedures at the time of the study. Real-time measurement of radiation dose to patients and staff during these procedures was done. To the patients, kerma-area product (KAP) and fluoroscopy time measurements were done using an in-built KAP meter, while peak skin dose (PSD) was measured using slow Extended Dose Range (EDR2®) radiographic films. The staff occupational doses were measured using individual thermoluminescence dosemeters. The maximum and minimum KAP values were found to be 137.1 and 4.2 Gy cm2, while the measured PSD values were 740 and 52 mGy, respectively. The fluoroscopic time range was between 3.3 and 70 min. The staff doses per procedure ranged between 0.05 and 1.41 mSv for medical doctors, 0.03 and 1.16 mSv for nurses, 0.04 and 0.78 mSv for radiographers and 0.04 and 0.88 mSv for clinical staff. The measured patient PSDs were within the threshold limit for skin injuries. However, with the current few IP specialists, an annual increase in workload as determined in the study will result in the International Commission on Radiation Protection annual eye lens dose limit being exceeded by 10 %. A concerted effort is required to contain these dose levels through use of protective gear, optimisation of practice and justification.
    URI
    Http://profiles.uonbi.ac.ke/christineyuko/publications/radiation-exposure-interventional-procedures
    http://erepository.uonbi.ac.ke:8080/xmlui/handle/123456789/29989
    Citation
    Radiation Exposure In Interventional Procedures , G. K. Korir1, B. O. Ochieng, J. S. Wambani, I. K. Korir, And Jowi Yuko C. , Radiat Prot Dosimetry (2012) Doi: 10.1093/rpd/ncs072 , (2012)
    Publisher
    University of Nairobi
     
    De[artment of Radiation Medicine
     
    Collections
    • Faculty of Health Sciences (FHS) [10418]

    Copyright © 2022 
    University of Nairobi Library
    Contact Us | Send Feedback

     

     

    Useful Links
    UON HomeLibrary HomeKLISC

    Browse

    All of UoN Digital RepositoryCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Copyright © 2022 
    University of Nairobi Library
    Contact Us | Send Feedback