    Microbial contamination of multi-use ophthalmic solutions in Kenya

    Thumbnail
    View/Open
    full text .pdf (106.2Kb)
    Date
    2007
    Author
    Nentwich, MM
    Kollmann, KH
    Meshack, J
    Ilako, DR
    Schaller, UC
    Type
    Article
    Language
    en
    Metadata
    Show full item record

    Abstract
    Contaminated ophthalmic solutions represent a potential cause of avoidable ocular infection. This study aimed to determine the magnitude and pattern of microbial contamination of multi-dose ocular solutions at the Department of Ophthalmology, University of Nairobi, at the Kenyatta National Hospital, Kenya. METHODS: 101 vials were obtained for microbial examination after an average use of 2 weeks. The dropper tip and the residual eye drop were examined for contamination. The specimens were cultured, the number of colonies counted, the organisms identified and susceptibility testing to selected antimicrobial agents was done. RESULTS: Six (6%) of the 101 analysed vials were contaminated: 4/77 vials (5%) from a multi-user setting and 2/24 vials (8%) from a single user setting. Three contaminations (3/38, 8%) occurred in vials from the eye ward, another three (3/59, 5%) in vials from the outpatient clinic. Most bacteria identified belonged to the normal commensal flora of the eye. Isolated contaminants were micrococci (n = 2), Staphylococcus epidermidis, Haemophilus sp, Bacillus sp and a Gram negative rod. The dropper tip was more often contaminated (n = 6) than the residual solution (n = 1), and only one vial showed a contamination of both the drop and the tip. CONCLUSION: Our data show a contamination rate of 6%, which is in the lower range of data published on the contamination of eye drops elsewhere (0.07% to 35.8%)
    URI
    http://erepository.uonbi.ac.ke:8080/xmlui/handle/123456789/30686
    http://www.ncbi.nlm.nih.gov/pubmed/17475714
    Citation
    Br J Ophthalmol. 2007 Oct;91(10):1265-8
    Publisher
    Department of Opthalmology, University of Nairobi
     
    Department of Medical Microbiology, University of Nairobi, Kenya.
     
    Collections
    • Faculty of Health Sciences (FHS) [10418]

    Copyright © 2022 
    University of Nairobi Library
    Contact Us | Send Feedback

     

     

    Useful Links
    UON HomeLibrary HomeKLISC

    Browse

    All of UoN Digital RepositoryCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Copyright © 2022 
    University of Nairobi Library
    Contact Us | Send Feedback