Show simple item record

dc.contributor.authorVan Kets, H
dc.contributor.authorThiery, M
dc.contributor.authorWildemeersch, D
dc.contributor.authorDelbarge, W
dc.contributor.authorVrijens, M
dc.contributor.authorVan der Pas, H
dc.contributor.authorParewijck, W
dc.contributor.authorTemmerman, M
dc.contributor.authorVan Trappen, Y
dc.contributor.authorVan den Ostende, G
dc.date.accessioned2013-06-26T13:59:02Z
dc.date.available2013-06-26T13:59:02Z
dc.date.issued1996
dc.identifier.citationContracept Fertil Sex. 1996 Dec;24(12):908-11en
dc.identifier.urihttp://hinari-gw.who.int/whalecomwww.ncbi.nlm.nih.gov/whalecom0/pubmed/9026279
dc.identifier.urihttp://erepository.uonbi.ac.ke:8080/xmlui/handle/123456789/40588
dc.description.abstractGyneFix, conceived in 1985, was developed to minimize three major problems frequently associated with discontinuation of IUD use: expulsion, bleeding and pain. Since the initial clinical investigations, over 10,000 women years of experience and up to 8 years of follow-up in international, multicenter, non-comparative and comparative clinical trials, including a large proportion of nulligravid/nulliparous women, have been collected. The following conclusions were reached: 1. The unique design characteristics of GyneFix (frameless, flexible and fixed to the fundus of the uterus) have resulted in optimal tolerance and almost complete absence of expulsion. The result is enhanced effectiveness (comparable to OCs and male/female sterilization) and a high rate of continued use. GyneFix reduces the IUD-failure rate to a minimum and is, therefore, a welcome reversible alternative to OCs and female surgical contraception. 2. Frameless and flexibility explain the absence of side-effects and adverse events caused by dimensional incompatibility between the frame of conventional IUDs and the uterine cavity and may also explain the absence of PID and ectopic pregnancies in any of the clinical studies. 3. Insertion of GyneFix, with or without local anaesthesia, is easily accomplished in the office of a few minutes. Removal is easy, quick and painless. 4. GyneFix is an equally effective and well accepted method fro nulliparous womenen
dc.language.isoenen
dc.title[Intrauterine copper contraceptive implants]en
dc.typeArticleen
local.publisherService de Gynécologie et d'Obstétrie, Hôpital Universitaire de Gand, Belgiqueen
local.publisherDepartment of Obstetrics and Gynaecology, University of Nairobien


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record