• Login
    • Login
    Advanced Search
    View Item 
    •   UoN Digital Repository Home
    • Conference/ Workshop/ Seminar/ Proceedings
    • Faculty of Health Sciences (FHS)
    • View Item
    •   UoN Digital Repository Home
    • Conference/ Workshop/ Seminar/ Proceedings
    • Faculty of Health Sciences (FHS)
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Assessment Of Quality Management In The Use Of Computed Tomography Machines In Kenya

    Thumbnail
    View/Open
    abstract.pdf (11.35Kb)
    Date
    2013-06
    Author
    Wambani, Jeska S
    Korir, Geoffrey K
    Type
    Presentation
    Language
    en
    Metadata
    Show full item record

    Abstract
    Background: The use of x-rays in radiation imaging is ever increasing in magnitude with increase in radiological procedures, and complexity of radiology equipment, Computed Tomography (CT) scanning included. Quality management with patient radiation dose monitoring is fundamental in optimising radiation protection and safety while optimising image quality. Objective: To assess the level of quality management with respect to quality assurance, image quality and patient dose in CT facilities in Kenya. Methodology: A quantitative method was developed and used to score the results obtained from the physical image quality, patient dose and quality assurance inspection results. Physical images were obtained from American Association of Physicists in Medicine (AAPM) water phantom, and patient dose measured using head and body phantoms. The results obtained were compared with internationally recognized standards including the European Guidelines Quality Criteria for CT and the International Basic Safety Standards for Protection against Ionizing Radiation. Study Design: A quality assurance inspection, physical image quality and patient dose assessment in eighteen representative CT facilities. Results: The overall findings placed the national quality management performance level at 57 ± 2% while patient dose, image quality and quality assurance administration performance were 71 ± 4%, 61 ± 3% and 40 ± 2%, respectively. Conclusion: The national level in quality management system in diagnostic radiology was benchmarked as good. Diagnostic Reference Levels (DRLs) were proposed in order to enhance the optimization of radiological protection of patients in Kenya. In future, we hope to demonstrate optimization of patient dose using typical patient dose in the new state-of-the-art multi-slice CT. Recommendation: Kenya should adopt Radiology facility accreditation system whereby a scrutiny of scores from each stage in the medical imaging chain is performed to enhance quality improvement.
    URI
    http://hdl.handle.net/11295/61070
    Citation
    Wambani, Jeska S.,Korir, Geoffrey K.; Assessment Of Quality Management In The Use Of Computed Tomography Machines In Kenya,presentation at the 2nd International Scientific Conference, CHS And KNH, 19th - 21st June 2013.
    Publisher
    University of Nairobi
     
    College of Health Sciences
     
    Collections
    • Faculty of Health Sciences (FHS) [852]

    Copyright © 2022 
    University of Nairobi Library
    Contact Us | Send Feedback

     

     

    Useful Links
    UON HomeLibrary HomeKLISC

    Browse

    All of UoN Digital RepositoryCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Copyright © 2022 
    University of Nairobi Library
    Contact Us | Send Feedback