    Effects of Distributed Generation penetration on system power losses and voltage profiles

    Thumbnail
    Date
    2013
    Author
    Abungu, Nicodemus
    Type
    Article
    Language
    en
    Metadata
    Show full item record

    Abstract
    In present times, the use of DG systems in large amounts in different power distribution systems has become very popular and is growing on with fast speed. Although it is considered that DG reduces losses and improves system voltage profile, this paper shows that this is not always true. The paper presents a GA-IPSO based approach which utilizes combined sensitivity factor analogy to optimally locate and size a multi-type DG in IEEE 57-bus test system with the aim of reducing power losses and improving the voltage profile. The multi-type DG can operate as; type 1 DG (DG generating real power only), type 2 DG (DG generating both real and active power) and type 3 DG (DG generating real power and absorbing reactive power). It further shows that though the system losses are reduced and the voltage profile improved with the location of the first DG, as the number of DGs increases this is not the case. It reaches a point where any further increase in number of DGs in the network results to an increase in power losses and a distortion in voltage profile.
    URI
    https://profiles.uonbi.ac.ke/abunguodero/publications/effects-distributed-generation-penetration-system-power-losses-and-voltage-
    http://hdl.handle.net/11295/64485
    Citation
    C KJ, O AN. "Effects of Distributed Generation penetration on system power losses and voltage profiles." International Journal of Scientific and Research Publications. 2013;3(12):1-8.
    Publisher
    University of Nairobi
    Collections
    • Faculty of Engineering, Built Environment & Design (FEng / FBD) [1465]

    Copyright © 2022 
    University of Nairobi Library
    Contact Us | Send Feedback

     

     

    Useful Links
    UON HomeLibrary HomeKLISC

    Browse

    All of UoN Digital RepositoryCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Copyright © 2022 
    University of Nairobi Library
    Contact Us | Send Feedback