    Establishing Diagnostic Reference Levels For Interventional Procedures In Kenya

    Thumbnail
    Date
    2013-11
    Author
    Korir, Geoffrey K
    Wambani, Jeska S
    Yuko-Jowi, Christine A
    Korir, Ian K
    Tries, Mark
    Kidali, Mike M
    Type
    Article
    Language
    en
    Metadata
    Show full item record

    Abstract
    Purpose To quantify ionizing radiation exposure to patients during interventional procedures and establish national diagnostic reference levels (NDRLs) for clinical radiation exposure management. Methods The cumulative reference point air kerma, kerma area product, fluoroscopy time and other operational parameters were monitored for 50 children and 261 adult patient procedures in five catheterization medical laboratories in Kenya. To estimate the risk associated with the exposure, effective doses were derived from the kerma area product using conversion factors from Monte Carlo models. Results About 3% of the measured cumulative reference point air kerma for the interventional procedures approached the threshold dose limit with the potential to cause deterministic effects such as skin injuries. In interventional cardiology, the results obtained for both children and adults indicated 33% were below the diagnostic reference levels (DRLs). In adult interventional radiology, 29% for cumulative reference point air kerma, and 43% for kerma area product and fluoroscopy time respectively were below the diagnostic reference levels. NDRLs were proposed for routine use in the procedures considered and for the non-existent DRLs situations in paediatric interventional cardiology. Conclusion The measured patient doses were above the DRLs available in the literature indicating a need for radiation optimization through, continuous monitoring and recording of patient dose. To promote radiation safety, facilities performing interventional procedures need to establish a radiation monitoring notification threshold for possible deterministic effects, in addition to the use of the newly established national diagnostic reference levels, as a quality assurance measure.
    URI
    http://www.sciencedirect.com/science/article/pii/S1078817413001223
    http://hdl.handle.net/11295/65437
    Citation
    Radiography Available online 14 November 2013
    Publisher
    Universty of Nairobi
    Subject
    Radiation exposure; Diagnostic reference levels; Patient dosimetry; Interventional procedures
    Collections
    • Faculty of Health Sciences (FHS) [10417]

    Copyright © 2022 
    University of Nairobi Library
    Contact Us | Send Feedback

     

     

    Useful Links
    UON HomeLibrary HomeKLISC

    Browse

    All of UoN Digital RepositoryCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Copyright © 2022 
    University of Nairobi Library
    Contact Us | Send Feedback