    Minimal cross-infection risk through Icare rebound tonometer probes: a useful tool for IOP-screenings in developing countries

    Thumbnail
    View/Open
    ABSTRACT.pdf (10.09Kb)
    Date
    2010
    Author
    Briesen, S
    Schwering, M Schulze
    Roberts, H
    Kollmann, M
    Stachs, O
    Behrend, D
    Schäfer, St
    Guthoff, R
    Type
    Article; en
    Language
    en
    Metadata
    Show full item record

    Abstract
    Aims Recently, a new rebound tonometer has been introduced into the market, which might be useful for glaucoma screenings in developing countries. Disposable probes, that are potentially reusable, are recommended by the manufacturer. Our study aimed to address the question of microbial transmission risks if the probes are reused. Methods IOP measurements were obtained from 100 healthy eyes. The used probes were inoculated on broth and culture media. In addition, 10 probes were analyzed using environmental scanning electron microscopy in saturated hydrogen-steam atmosphere after usage and wipe disinfection technique with Sekusept 4% solution or Isopropanol 70%. Results No bacterial or fungal growth could be detected in any of the inoculated agar plates or broth tubes. No microorganisms, clumps of cells, or single intact epithelium cells were detected in any of the probes using environmental scanning electron microscopy. Cell debris was detected on seven probes; three probes were completely free of any residual cell elements. Conclusion Transmission of possibly infective material through reused probes is significantly less than for reusable Goldmann probes if the same sterilization protocols are applied. Re-usage of the probes appears safe and is helpful in avoiding unnecessary costs.
    URI
    http://hdl.handle.net/11295/72800
    Citation
    Eye (2010) 24, 1279–1283
    Publisher
    University of Nairobi,
    Subject
    rebound tonometer; transmission; cross-infection; disinfection; glaucoma; developing countries
    Collections
    • Faculty of Health Sciences (FHS) [10417]

    Copyright © 2022 
    University of Nairobi Library
    Contact Us | Send Feedback

     

     

    Useful Links
    UON HomeLibrary HomeKLISC

    Browse

    All of UoN Digital RepositoryCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Copyright © 2022 
    University of Nairobi Library
    Contact Us | Send Feedback