    Development of a flat-plate solar milk pasteuriser for arid pastoral areas of Kenya

    Thumbnail
    View/Open
    Main Article (530.8Kb)
    Date
    2011-09
    Author
    Wangoh, J.
    Okoth, M. W.
    Wayua, F. O.
    Type
    Presentation; en
    Language
    en
    Metadata
    Show full item record

    Abstract
    Milk marketing is an important income earning opportunity for people in arid pastoral areas of Kenya. To minimise losses along the milk chain, traders boil milk using scanty wood fuel which negatively affects the environment. The abundant solar radiation in these areas could be explored for its suitability for milk processing. Therefore, a solar milk pasteuriser consisting of flat-plate water heating collector and a 1.5 mm thick stainless steel cylindrical milk vat was designed and tested in an arid pastoral area of Kenya. The milk vat had a capacity of80 litres and a 50 mm wide hot water jacket insulated with 38 mm thick fibreglass. Hot water produced by the collector was used for pasteurising milk. Parameters measured included the maximum achievable water temperature, maximum amount of milk to be pasteurised, temperature of milk, temperature of hot water, total bacterial count and coliform in the pasteurised milk, solar radiation, ambient temperature and wind speed. Maximum milk temperature inversely varied with the amount of milk, reaching 81.4 DC with 20 litres and 41.7DC with 70 litres. The optimum quantity of milk that could be pasteurised by this device was 40 litres, heated to 69.TDC in an average of 1.3±0.1 hours, at an average insolation and ambient temperature of 22.5±0.9 Ml.mi.day" and 29.8±0.1 DC, respectively. The average temperature difference between hot water and milk being pasteurised was 8.1±0.6DC. Total bacterial counts in pasteurised milk were less than 10 cfu.ml' while coliform counts were negative. The system had a payback period of 4.3 years. This low-cost solar milk pasteuriser is appropriate for arid pastoral areas without grid electricity, where milk marketing is an important income source, and where most of the milk is boiled using firewood.
    URI
    http://hdl.handle.net/11295/73228
    Citation
    Optimimization of Agricultural Value Chains for sustainable Development
    Sponsorhip
    National Council of Science and Technology, The Kenya Seed Company
    Publisher
    Faculty of Agriculture, University of Nairobi
    Subject
    performance
    design,
    Flat-plate solar milk pasteuriser,
    Description
    aGRO 2011 biennial conference presentation
    Collections
    • Faculty of Agriculture & Veterinary Medicine (FAg / FVM) [1902]

    Copyright © 2022 
    University of Nairobi Library
    Contact Us | Send Feedback

     

     

    Useful Links
    UON HomeLibrary HomeKLISC

    Browse

    All of UoN Digital RepositoryCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Copyright © 2022 
    University of Nairobi Library
    Contact Us | Send Feedback